Reading command tables, Command tables, 89 appendices – Kenwood TS-870S User Manual

Page 95

Advertising
background image

89

APPENDICES

READING COMMAND TABLES

q Command
w Name
e Function of the command
r The format of the command is shown. When oblique lines are drawn in the 1st and 2nd columns, there is no Set

command.

t The format of the command for reading the transceiver’s current status is shown. When oblique lines are drawn in

the 1st and 2nd columns, there is no Read command.

y The format of the command output from the transceiver is shown. When oblique lines are drawn in the 1st and 2nd

columns, there is no Answer command.

u The number of command digits is shown.
i Corresponds to the parameter of the command format.
o Corresponds to the Format number in the Parameter Table. For the parameter formats, refer to the Parameter

Table {page 84}.

!0 Indicates the function of the parameter.

COMMAND TABLES

Note:

Parameters that have a Parameter Function of “NOT USED” are not supported by the TS-870S. Any character except the ASCII control

codes (00 to 1Fh) and the terminator (;) may be entered for those parameters.

1

Auto information OFF/ON

AI

AUTO INFORMATION

2

Parameter Format

Parameter function

P1

32

AI NUMBER

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

A

I

P1

A

I P1

;

A

I

;

4

5

6

7

8

9 10 11 12 13 14

;

Note:
For other commands, controls whether
changing a parameter will or will not trigger
the corresponding Answer command
to be output.

Ex:
For IF, the Answer command is output
if the step frequency or RIT/XIT
frequency is changed.

1

Sets or reads AF gain.

AG

AF GAIN

2

Parameter Format

Parameter function

P1

31

AF GAIN

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

A

G

P1

;

A

G

;

4

5

6

7

8

9 10 11 12 13 14

P1

A G

;

1

Selects antenna connector ANT 1/ ANT 2.

AN

ANTENNA NUMBER

2

Parameter Format

Parameter function

P1

33

ANTENNA
NUMBER

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

A

N P1

A

N P1

;

A

N

;

4

5

6

7

8

9 10 11 12 13 14

;

1

Antenna Tuner THRU/IN -LINE, and tuning START/CANCEL

AC

ANTENNA TUNER CONTROL

Note:
P1 is used for Answer only.
Tuning cannot be started if P2 is in the
THRU state (If P2="0", selecting "1" for P3
does not start tuning).
P1: RX THRU/IN P2: TX THRU/IN

2

Parameter Format

Parameter function

P1

P2

P3

30

30

1

TUNE THRU/IN

(Answer Only)

TUNE THRU/IN

TUNE OFF/ON

3

4

5

6

7

8

9 10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9 10 11 12 13 14

1

2

3

A

C

P2 P3 ;

A

C P1 P2 P3 ;

A

C

;

4

5

6

7

8

9 10 11 12 13 14

1

Antenna Tuner THRU/IN -LINE, and tuning START/CANCEL

AC

ANTENNA TUNER CONTROL

Note:
P1 is used for Answer only.
Tuning cannot be started if P2 is in the
THRU state (If P2="0", selecting "1" for P3
does not start tuning).
P1: RX THRU/IN P2: TX THRU/IN

2

Parameter Format

Parameter function

P1

P2

P3

30

30

1

TUNE THRU/IN

(Answer Only)

TUNE THRU/IN

TUNE OFF/ON

3

4

5

6

7

8

9

10 11 12 13 14

Input

Function

Output

Set

Read

Answer

1

2

3

4

5

6

7

8

9

10 11 12 13 14

1

2

3

A

C

P2 P3

;

A

C

P1 P2 P3

;

A

C

;

4

5

6

7

8

9

10 11 12 13 14

q

u

i

o

!0

w

r

t

y

e

Advertising