SERVICE TECH. INFORMATION

SECTION 5

19

5A.

TROUBLESHOOTING

Keep this manual with your water softener. If repairs are needed, the service technician must have the

information on the following pages. For telephone assistance, call toll free, 1-800-426-9345.

SELECT

ON/OFF

HOLD

RECHARGE TONIGHT

RECHARGE NOW

DOWN
button

UP button

display

SELECT button

ON/OFF–HOLD button
(Recharge Tonight–Now)

Demand Water Softener

Sears Water Line

for Customer Assistance

1–800–426–9345

Kenmore

ALWAYS MAKE THESE INITIAL CHECKS FIRST

1. Does the time display show the correct time of day?

- If display is blank, check power source to the

softener.

- If time is flashing, power was off for over 6 hours.

The softener resumes normal operation but regenĆ

erations occur at the wrong time.

- If an error code (Example: Err 03) shows in the face

plate display, go to Automatic Electronic DiagnosĆ

tics.

2. Plumbing bypass valve(s) must be in Full Service

position.

3. The inlet and outlet pipes must connect to the

softener valve inlet and outlet respectively.

4. Is the transformer plugged into a live", grounded

wall outlet, and is the power cable fastened securely?

5. The valve drain hose must be free of kinks and sharp

bends, and not elevated over 8 ft. above the floor.

REMOVE THE TOP COVER AND SALT TANK COVER

6. Is there salt in the storage tank?
7. Is the brine tubing connected? (See water flow

diagrams).

8. Is the brine valve float set right? (See page 22).
9. Press the SELECTbutton 2 times to display the

hardness setting. Be sure it is the correct setting for

the household's water supply. (Make a hardness test

of the raw water and compare with the hardness

setting. Also test a soft water sample to verify if a

problem exists.) Press SELECTtwice more to return

the time of day display.

If you do not find the problem after making initial checks,

do the Manual Initiated Electronic Diagnostics, and the

Manual Advance Regeneration Check.