Service tech. information, 5c. water flow through the softener valve – Kenmore 625.348420 User Manual

Page 25

Advertising
background image

SERVICE TECH. INFORMATION

SECTION 5

25

5C. WATER FLOW THROUGH THE SOFTENER VALVE

BRINING AND BRINE RINSE CYCLES

After fill, timer/switch action allows the motor to turn the rotor and disc into BRINING

position. Water flow is directed to the nozzle. Suction, created by the nozzle and venturi,

draws brine from the salt storage tankand injects it into the resin bed via the bottom

distributor. Flow continues out the top distributor and to the drain. Hard water is available

at the valve outlet.

When the brine valve closes to end brine draw, water flow continues in the same

directions to slowly RINSE brine from the resin bed and to the drain.

drain

brine from salt

storage tank

nozzle

venturi

bypass

hard water

to valve

outlet

from Valve Inlet

(hard water)

BACKWASH CYCLE

Timer/switch action again allows the motor to turn the

rotor & disc to place the valve in BACKWASH, stopping

water flow to the nozzle. Water is routed down and out the

bottom distributor, up through the bed, and out the top

distributor to the drain. The fast flow (controlled by a flow

plug in the drain fitting) flushes dirt, sediments, iron

deposits, remaining brine and hardness to the drain.

drain

flow plug

bypass

hard water

to valve

outlet

Advertising