TROUBLESHOOTING

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valve

motor, brine tank fill, brine draw, regeneration flow

rates, and other controller functions. Always make

the initial checks, and the manual initiated

diagnostics.

NOTE:

The face plate display must show a steady

time (not flashing).

1

.

Press the ON/OFFĆHOLD button and hold in for

3 seconds. RECHARGE NOW begins to flash as

the softener enters the fill cycle of regeneration.

Remove the brinewell cover and, using a

flashlight, observe fill water entering the tank.

A

.

Ifit does not enter the tank, look for an obĆ

structed nozzle, venturi, fill flow plug, brine tubĆ

ing, or brine valve riser pipe.

CYCLE FLOW RATES (GALLONS PER MIN.)

FILL (flow to salt storage tank)

0.3 (1.1 liters)

BRINING

.16 (.6 liters)

BRINE RINSE

(flow to drain)

.11 (.4 liters)

BACKWASH

(flow to drain)

1.8 (6.8 liters)

FAST RINSE

1.8 (6.8 liters)

2

.

After observing fill, press the ON/OFFĆHOLD

button to move the softener into brining. A slow

flow of water to the drain will begin. Verify brine

draw from the brine tank by shining a flashlight

into the brinewell and observing a noticeable

drop in the liquid level.

NOTE:

Be sure a salt bridge is not preventing water

with salt contact.

A

.

Ifthe softener does not draw brine:

- nozzle and/or venturi dirty or defective.

- nozzle and venturi not seated properly on gasĆ

ket.

- restricted drain (check drain fitting and hose).

- defective nozzle and venturi seal.

- other inner valve defect (rotor seal, rotor &

disc, wave washer, etc.).

NOTE:

Ifwater system pressure is low, an elevated

drain hose may cause back pressure, stopping brine

draw.

3

.

Again press ON/OFFĆHOLD to move the softenĆ

er into backwash. Look for a fast flow of water

from the drain hose.

A

.

An obstructed flow indicates a plugged top disĆ

tributor, backwash flow plug, or drain hose.

4

.

Press ON/OFFĆHOLD to move the softener into

fast rinse. Again look for a fast drain flow. Allow

the softener to rinse for a few minutes to flush out

any brine that may remain in the resin tank from

the brining cycle test.

5

.

To return the softener to service, press ON/OFFĆ

HOLD.

BRINE VALVE

FLOAT SETTING

(Distance from top of resin tank, to top of resin bed.)

FREEBOARD

14” – 18”

10”

Advertising