Service tech. information, 5a. troubleshooting, Sr 17 – Kenmore 625.348420 User Manual

Page 21

Advertising
background image

SERVICE TECH. INFORMATION

SECTION 5

21

5A.

TROUBLESHOOTING

CORRECT

SWITCH

DISPLAYS

VALVE CYCLE STATUS

– –

Valve in service, fill, brining, back-
wash or fast rinse position

– P

Valve rotating from one position to
another

C. While in this diagnosticscreen, the following inĆ

formation is available and may be beneficial for

various reasons. This information is retained by

the computer from the first time electrical power

is applied to the face plate.
-- Press

to display the number of days this

face plate has had electrical power applied.

-- Press

to display the number of regeneraĆ

tions initiated by this face plate since the SR code

number was entered.

2. Press the SELECT button and hold 3 seconds unĆ

til

SR 17

shows.

This code identifies the softener nominal capacity

size. If the wrong number shows, the softener will

operate on incorrect programming. Do the following

as needed.

Return the present time display: Press the

SELECT button.

Change the SR number: To display the correct SR

number, press the UP or DOWN

button. Press

SELECT, and reset the timer.

NOTE:

If the face plate is left in a diagnostic display (or a

flashing display when setting times or hardness),

present time automatically returns if a button is not

pressed within 4 minutes.

FACE PLATE REPLACEMENT: Be sure the valve is

in service position (observe valve cycle indicaĆ

tor) when replacing the face plate.

If, after installing and programming the replaceĆ

ment face plate, the valve is not in service position,

do the following to assure correct cycle orientation,

or timing, between the face plate and valve.

Use the MANUAL ADVANCE procedures, page 22.

With the RECHARGE NOW button, advance

through the recharge cycles until the valve stops in

service position, and RECHARGE no longer flashes

in the timer.

NOTE: The valve motor may automatically drive

through several valve positions while searching for

service. If an error code occurs, unplug the transĆ

former, then plug in again.

CAM

MOTOR

position
markers

Advertising