DESCRIPTION

D E F A U L T

RANGE

DOR R OFF

controls the duration of ringing at the door

030SEC 1~250SEC

(Door Ring

ring destination before canceling

OFF time)

FIRST DGT

controls how long the system will wait for

025SEC 1~250SEC

(First Digit

dialing to begin before dropping the dial tone

wait time)

and initiating an error tone.

HOOK OFF

controls the time before dial tone is sent to a

0200MS

100~

(Hook OFF

single-line station.

2500MS

time)

INTER DGT

controls the grace period between dialing

025SEC 1~250SEC

(Inter Digit

valid digits before dropping the call and

duration)

returning the user back to an error tone.

MMC OUT

controls the grace period between programming

030SEC 1 0 ~ 2 5 0 S E C

(MMC

actions while in a programming session, before

session time)

returning system to secure programming status.

OFF R INT

controls the duration of time between ring

015SEC 1~250SEC

(Off hook

bursts to a user who has a camped-on call.

Ring Interval)

PAGE MAX

controls the allowed duration of a page

020SEC 1~250SEC

(Page duration) announcement.

RCAL DISC

this is the time an attendant recall will

002MIN 1~250MIN

(Recall

ring before being disconnected.

Disconnect
time)

RCAL RING

this is the length of time a transfer recall

015SEC 0~250SEC

(Recall Ring

will ring at a station before recalling the

length)

operator

RCAL WAIT

after a transferred call is recalling at the transferring 015SEC 0~250SEC

(Recall

station and the station is busy, this timer will expire

Waiting time)

and transfer the call to the operator.
This only applies to trunk calls.

RCAL HOLD

determines the time calls can be left on hold

045SEC 0~250SEC

(Recall Hold

before recalling back to the holding station.

time)

RCAL TRSF

determines the time transferred calls ring

045SEC 0~250SEC

(Recall

before recalling.

Transfer time)

SLT F MIN

monitors the duration of a hookswitch flash to ensure that

0350MS

100~

(minimum SLT

the flash is valid and not a line transient or accidental

2500MS

Flash time)

hookswitch bounce. It is the minimum time of single-line station.

SLT F MAX

maximum time of hookswitch flash of a

0800MS

100~

(maximum SLT

single-line station.

2500MS

flash time)

SMDR PULS

this grace period timer starts SMDR recording

030SEC 1~250SEC

(SMDR start

for pulse (rotary) dialing and controls the

time for rotary LCD duration timer on the keysets.
dialing)

SMDR DTMF

this grace period timers starts SMDR recording

015SEC 1~250SEC

(SMDR start

for DTMF (Touch Tone) dialing and controls

time for touchtone the LCD duration timer on the keysets.
dialing)

TRK DISC

controls the duration of an outside call

030MIN 1~250MIN

NX-SERIES

HYBRID KEY SYSTEM

PROGRAMMING SECTION

MMC 50