Mmc 57 call cost mmc 60 toll deny table/apply – Samsung NX-308 User Manual

Page 124

Advertising
background image

This MMC is used to program the unit cost of the metering pulse generated by the Central
Office. If the MPD card is installed, it will detect the metering pulse provided by Central
Exchange and determine the call cost by the number of metering pulses and unit cost
programmed via this MMC. The unit cost is a four (4)digit number, and is measured in the
minimum money denomination in the country of use.

PROCEDURE

LCD DISPLAY

1. Press [TRANSFER] and dial 57

Display shows

2. Enter the 4-digit unit cost.

If you don't enter 4 digits, the existing data will not be
changed.

3. Press [TRANSFER] to save and exit

DEFAULT DATA

UNIT COST : 0000
(The range of the CALL COST is 0001 ~ 9999)

RELATED MMC

NONE

This MMC enables you to define which leading digit(s) in a dialing plan are to be restricted and
which class(es) should be applied in this toll deny table. Each entry can define up to 11 digits.

PROCEDURE

LCD DISPLAY

1. Press [TRANSFER] and dial 60

2. Press [MUTE] or [MESSAGE] select the search class

(search class = NEW, ALL, B,C,D,E)

3. Press [VOLUME (-) or (+)], to find the desired entry or

an empty entry

4. Enter the dial number to be restricted and press [ C A L L B A C K ]

to assign the toll restriction apply class And dial four(4) digits,
0 for NO

1 for YES

5. Press [TRANSFER] to save and exit

DEFAULT DATA

NONE

RELATED MMC

MMC 30 STATION TOLL CLASS
MMC 61 TOLL ALLOW TABLE/APPLY
MMC 65 ASSIGN WILD CHARACTER

NX-SERIES

HYBRID KEY SYSTEM

PROGRAMMING SECTION

MMC 57

CALL COST

MMC 60

TOLL DENY TABLE/APPLY

Advertising