Calibration Utility for MICROSOFT WINDOWS

1–14

September 1997 Part No. 1H9659

Easy Cal Step 5

Use the test print to calibrate your printer in the Easy Cal Step 5 dialog box.

1. Look at the test print and decide which grayscale cluster appears

the most neutral gray.

NOTE: If you want to print another test print, click on the

<<Back button

to return to the Easy Cal Step 4 dialog box.

2. Type the number of the most neutral grayscale cluster in the

Cluster

Number text box.

NOTE: If you want to print an updated test print, you can click on the

<<Back button to return to the Easy Cal Step 4 dialog box.

If cluster number 225 on the updated test print is the most neutral
gray, then the calibration is successful. Type 225 in the

Cluster

Number text box and go to step 3.

3. Click on the

Done button.

The printer calibration begins. When the calibration is complete, the
following dialog box appears.