Temporary Delete

If a key is programmed with the Temporary Delete or
Scan + Temporary Delete function, you can temporarily
remove specific channels from the scanning sequence
during Scan. When Scan stops at a channel, you can
remove that channel from the scanning sequence by
pressing and holding the key programmed as Temporary
Delete
or Scan + Temporary Delete for 1 second.

You cannot delete the Priority channel, if one has been
set up.

You cannot delete a channel if there will be less than
2 channels available for scanning remaining.

To add the channel back into the Scan list, simply exit
Scan mode or switch the transceiver OFF and then ON
again.

Revert Channel

During Scan, pressing the PTT switch to transmit will
cause the transceiver to select the revert channel. Your
dealer can program the revert channel using one of the
following methods:

Selected: The last channel selected is assigned as
the new revert channel.

Selected + Talkback: If the channel has been
changed during Scan, the newly selected channel is
assigned as the new revert channel. However, the
transceiver also transmits on the channel where Scan
is currently paused.

Priority: If your dealer has programmed a Priority
channel, it is the revert channel.

Priority + Talkback: If your dealer has programmed a
Priority channel, it is the revert channel. However, the
transceiver also transmits on the channel where Scan
is currently paused.