1 - pcb removal and replacement, Operate. refer to, Section 5.4.1, “pcb removal and – KVH Industries TracVision L2 User Manual

Page 47: Replacement, For details on the fuse location and, 1 pcb removal and replacement

Advertising
background image

5-5

Maintenance

54-0195 Rev. A

5.4.1 PCB Removal and Replacement

Estimated Time to Repair:

1

2

hour

The microprocessor PCB assembly is protected by a cover
fastened to the rotating plate

Fig. 5-1

. The cover must be

removed to gain access to the main power fuse and the PCB
assembly.

1. Using needle-nose pliers, remove the E-ring from

one end of the connecting rod

Fig. 5-2.

2. Remove the connecting rod by sliding it off the

bracket.

3. Fully retract the elevation axis motor shaft

– Fig. 5-5.

4. Remove 6 pan head screws from the PCB cover

flanges.

5. Remove the PCB cover. To get the necessary

clearance, rotate the linear actuator up 90º while
lifting the PCB cover – Fig. 5-5.

6. Remove all cable connectors from the PCB.

Figure 5-6 on the following page illustrates the
PCB arrangement and connector locations.

TracVision L2 is equipped with a
5x20 mm, 3.15-amp, 250 volt fast-
blow fuse, which is mounted on the
PCB. To access and replace the
fuse, remove the PCB cover.

When carrying out maintenance
on the PCB, be sure to not drop
any of the small screws inside the
mechanism. If a screw is lost within
the baseplate, it must be retrieved
to avoid causing any damage when
the unit rotates.

PCB Cover

Linear Actuator

Elevation Axis

Motor Shaft

Figure 5-5
Removing the PCB Cover

Advertising