9. Type

ZAP<cr>

. The system will re-initialize using

the new RFGAIN and RFOFFSET scale factors
displayed following Step 7.

10. Wait for the system to perform the background

noise calculation. Read the Average Noise Level
value from the messages transmitted out the
maintenance port. This value must be greater than
300 and less than 1300. An example of the message
sequence and format is as follows:

*** Averaging Background Noise ***

Average Noise Level = 750

Noise Threshold = 1450

11. Wait for the system to search for, find the satellite,

enter Tracking Mode and track the satellite for a
minimum of 30 seconds. Record the average RF
signal value reported from the +POS: AZ, EL, RF
messages. An example of the message sequence
and format is as follows:

+POS: 154.5 33.2 2521

12. The RF signal values while tracking shall be

greater than 2000 and less than 3000.

5-9

Maintenance

54-0195 Rev. A