Appendix e - startup data sequences, E.1 - system connected to ird data, Vided in – KVH Industries TracVision L2 User Manual

Page 59: Appendix e, As detailed in, Appendix e startup data sequences, E.1 system connected to ird data

Advertising
background image

Appendix E
Startup Data Sequences

The data on the following pages presents the startup data
sequences registered by the TracVision L2. The first section shows
the sequences registered by a system that is connected to an IRD
low-speed data port. The second section shows the sequences
registered by a system that is NOT connected to an IRD low-speed
data port. Both sections show two routines. One is the standard,
full initialization routine; the second is that registered by
TracVision L2 if it is turned on and acquires the satellite via the
“Instant On” operation (described in

Section 3, “Using Your

TracVision L2”

). These sequences can be recorded using the data

port and a PC.

E.1

System Connected to IRD Data

Standard Startup Sequence

?PGM

KVH TracVision L2 Rev X - Version X.XX - Serial number XXXXXXXX

Limit Switch Test

Limit Switch Status:PASS ------------------Pass is expected

*** Initializing IRD ***

IRD STATUS: PASS DSS -------------------PASS is expected with successful IRD identification

Saved Sat Pos: EL = 36.5

*** Initializing Rate Bias ***

+POS: 45.0 45.9 548

VEL_INDEX: Az = 1996, El = 2182 ----------Expected range is 1700-2300

RATE BIAS: PASS ---------------------------Az & El values above are within valid ranges

*** Averaging Background Noise ***

+POS: 45.0 22.5 356

+POS: 135.0 20.0 362

+POS: 311.8 20.0 355

Average Noise Level = 381

Noise Threshold = 859

Saved Sat Pos: EL = 36.5

*** Entering Search Mode 1 ***

+POS: 27.0 20.1 354

+POS: 79.9 36.4 341

Satellite Found: AZ = 62.26, EL = 36.50, RF = 1300

+POS: 53.6 36.5 449

E-1

Startup Data Sequences