TROUBLESHOOTING & REPAIR

F-4

F-4

LN-9 Wire Feeder

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

FUNCTION PROBLEMS

No wire feed when gun trigger is
activated. The digital meter does
NOT light. The drive rolls do not
turn.

1. Make sure 115VAC is being

applied to the LN-9 at the input
connector. Pin "C" is lead #31
and pin "D" is lead #32.

2. Check the 5 amp circuit breaker.

Reset if tripped.

3. The F101 1/2 amp fuse, located

on the power PC board, may be
blown.

1. Check for loose or faulty lead

connections between the input
connector, the T1 transformer,
and the power PC board.

2. The T1 transformer may be

faulty. Perform the

T1

Transformer Test.

No wire feed when gun trigger is
activated. The digital meter DOES
light but reads zero in both (set and
actual) volts and wire speed.

1. The wire drive motor may be

over heated, and the thermal
protector has tripped. Let unit
cool.

1. Check for loose or faulty con-

nections on leads #527 and
#528 between the wire drive
motor and the power PC board.

2. Perform the

T1 Transformer

Test. Replace if faulty.

3. The power PC board may be

faulty. Replace.

Advertising