Test Meter PC Board Accuracy. (Metric Models Only)

1. Use a test meter with at least 3-1/2 digits and +/-

.5% accuracy.

2. Connect the + probe to lead called for in the table

below and the - probe to lead #510C.

NOTE: The coating will have to be removed from the
test points.

3. With the meter in SET M/MIN, adjust the speed con-

trol until the LN-9 meter matches the settings in the
table below. If the test meter does not match the
readings, the meter PC board may be faulty.
Replace the meter PC board.

TROUBLESHOOTING & REPAIR

F-41

F-41

LN-9 Wire Feeder

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

METER CIRCUIT ACCURACY TEST

(continued)

METRIC MODEL

METRIC RANGE

SET M/MIN READING

TEST VOLTMETER

READING

LN-9 or LN-9F

LO

8.89

LEAD #560

3.50 +/-.05VDC

HI

15.2

LEAD #561

6.00 +/-.07VDC

LN-9H or LN-9FH

LO

8.28

LEAD #560

2.00 +/- .05VDC

HI

24.8

LEAD #561

6.00+/-.07VDC