TEST PROCEDURE

1. Remove input power to the LN-9 wire feed-

er.

2. Using the phillips head screw driver, remove

the screws holding the left side cover
assembly.

3. Disconnect lead #532 from the power PC

board terminal. See Figure F.1.

Electric Shock can kill.

With power applied,
there are high voltages
inside the wire feeder.
Do not reach into the
wire feeder or touch any
internal part of the wire
feeder while power is
applied.

4. Apply power (115VAC) to the T1 transformer

primary leads #31 and #532. See Figure F.1
and the Wiring Diagram.

5. Using the volt-ohmmeter, check for 28VAC

at secondary leads #526 and #527. See
Figure F.1. Place the meter probes where
the leads attach to the power PC board ter-
minals.

WARNING

FIGURE F.1 – LEAD #532 AT POWER PC BOARD

115 VAC

T1
TRANSFORMER

LEAD 526

LEAD 532

LEAD 31

LEAD 527