TROUBLESHOOTING & REPAIR

F-40

F-40

LN-9 Wire Feeder

METER CIRCUIT ACCURACY TEST

(continued)

Test Digital Meter Accuracy. (For LN-9 models
above code 7980 with separable digital meter and
meter boards only).

1. Use a test meter with at least 3-1/2 digits and

+/- .5% accuracy.

2. Connect the + probe to TP4 and the - probe to

lead #510C.

NOTE: The coating will have to be removed from
the test points.

3. With the meter in SET volts, adjust the voltage

control until the test meter matches the set-
tings in the table below.

If the LN-9 digital meter does not match the
readings, the LN-9 digital meter may be faulty.
Replace the digital meter.

LN-9 SET VOLTS READING TEST VOLTMETER READING

15.0 V

.150 +/- .004 VDC

30.0 V

.300 +/- .004 VDC

60.0 V

.600 +/- .006 VDC

Test Meter PC Board Accuracy. (All Models)

1. Use a test meter with at least 3-1/2 digits and

+/- .5% accuracy.

2. Connect the + probe to leads #517 and the -

probe to lead #510C.

NOTE: The coating will have to be removed from
the test points.

3. With the meter in SET volts, adjust the voltage

control until the LN-9 meter matches the set-
tings in the table below.

If the test meter does not match the readings, the
meter PC board may be faulty. Replace the
meter PC board.

LN-9 SET VOLTS READING TEST VOLTMETER READING

15.0 V

1.50 +/- .05 VDC

30.0 V

3.00 +/- .05 VDC

60.0 V

6.00 +/- .07 VDC

Test Meter PC Board Accuracy. (For LN9-H,
LN-9FH Models Only)

1. Use a test meter with at least 3-1/2 digits and

+/- .5% accuracy.

2. Connect the + probe to lead #519 and the -

probe to lead #510C.

NOTE: The coating will have to be removed from
the test points.

3. With the meter in SET IN/MIN, adjust the

speed control until the LN-9 meter matches
the settings in the table below. If the test
meter does not match the readings, the meter
PC board may be faulty. Replace the meter
PC board.

LN-9 SET IN/MIN READING TEST VOLTMETER READING

082 IPM

0.50 +/- .05 VDC

49 IPM

3.00 +/- .05 VDC

978 IPM

6.00 +/- .07 VDC