TROUBLESHOOTING & REPAIR

F-15

F-15

LN-9 Wire Feeder

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

FEEDING PROBLEMS

When the gun trigger is activated
the drive rolls turn, but the wire will
not feed or wire feeding is rough.

1. Check or replace the gun cable.

It may be kinked, clogged, or
twisted.

2. Make certain the drive rolls and

guide tubes are correct for the
wire being used.

3. Check or replace the gun con-

tact tip.

4. The electrode wire may be rusty

or dirty. Replace if necessary.

1. If conditions are extremely dirty,

install a wiper on the wire before
it enters the guide tube. Use a
piece of cloth saturated with
"Pyroil B."

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.