Low weld output and low auxiliary output, Troubleshooting and repair, Caution – Lincoln Electric BULLDOG SVM208-A User Manual

Page 56

Advertising
background image

OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

Low weld output and low auxiliary
output.

1. The generator brushes may be

worn. See the Maintenance
Section
of this manual or contact
your local Lincoln Electric
Authorized Field Service Facility.

2. The engine RPM may be low.

1. Perform the Rotor Voltage

Test.

2. If the rotor voltage is low, the

field capacitor (C1) or bridge
(D2) may be faulty. Test or
replace.

3. Check the rheostat (R1).

Normal resistance is 3.3 ohm.
See the Rheostat Removal
and Replacement Procedure.

4. The rotor may be faulty. Per -

form the Rotor Resistance
Test
.

5. The engine RPM may be low.

Perform the Engine Throttle
Adjust ment Test
.

6. If engine idle RPM is okay, the

engine may have lost horse-
power and be in need of major
repair.

7. Perform Field Diode Test.

TROUBLESHOOTING AND REPAIR

F-8

F-8

BULLDOG® 140

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising