Troubleshooting and repair, Rotor voltage test (continued) – Lincoln Electric BULLDOG SVM208-A User Manual

Page 62

Advertising
background image

20

0A

LEAD 200A

CONNECTION

GROUND STUD

FIGURE F.1 – LOCATION OF LEAD 200A FOR ROTOR VOLTAGE TEST

ROTOR VOLTAGE TEST (continued)

PROCEDURE

1. With the 3/8” nut driver, remove the 4 sheet

metal screws that hold the top cover to the con-
trol box. Remove the top cover.

2. Start the machine and run it at high idle. Set the

output control (rheostat) at the MAXIMUM or
GENERATOR setting.

3. Set the volt/ohmmeter at the DC position.

4. Place the positive probe on lead 200A (Blue

and Brown wires joined together) where it con-
nects at the back of the rheostat. See Figure
F.1 for location. Place the negative probe on
the machine ground stud or any other good,
unpainted ground.

5. Check the voltage reading on the volt/ohmme-

ter. It should read 37.5 - 42.5 VDC.

6. If the voltage is low or not present, the genera-

tor field circuit is not functioning correctly.
Proceed with the Rotor Resistance Test. C1,
R1, or D2 may also be faulty.

7. If rotor voltage is correct, the generator field is

okay. Replace the top cover on the control box.
Tighten the 4 sheet metal screws with the 3/8”
nut driver.

TROUBLESHOOTING AND REPAIR

F-14

F-14

BULLDOG® 140

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising