Troubleshooting and repair, Typical weld output waveform – Lincoln Electric BULLDOG SVM208-A User Manual

Page 78

Advertising
background image

This is the typical AC output voltage
generated from a properly operating
machine. Note that each vertical divi-
sion represents 20 volts and that
each horizontal division represents 5
milliseconds in time. The machine
was loaded with a resistance grid
bank.

Note: Scope probes connected at
machine output terminals.

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

TYPICAL WELD OUTPUT WAVEFORM

MACHINE LOADED

0 volts

5ms

20 volts

50V

TROUBLESHOOTING AND REPAIR

F-30

F-30

BULLDOG® 140

MACHINE LOADED TO 125 AMPS AT 23 VAC