Service Manual 18

Disassembly

9. Capacitor

1. Remove the control box. (Refer to section 19)
2. Remove the knobs and the screw that fasten

control panel from control box.

3. Remove the screw that located in the front.
4. Open the bottom side of control box.
5. Remove the screw and the clamp that fastens

the capacitor.

6. Disconnect all the leads of capacitor terminals.
7. Re-install the components by referring to the

removal procedure, above. (See Figure 27)

10. Power Cord

1. Remove the control box. (Refer to section 19)
2. Open the control box. (Refer to section 25)
3. Disconnect the grounding screw from the control

box.

4. Disconnect the 2 receptacles.
5. Remove a screw which fastens the clip cord.

(See Figure 28)

6. Remove the power cord.
7. Re-install the component by referring to the

above removal procedure, above.
(Use only one ground-marked hole for ground
connection.)

8. If the supply cord of this appliance is damaged, it

must be replaced by the special cord. (The
special cord means the cord that has the same
specification marked on the supply cord attached
at the unit.)

11. Thermistor

1. Remove the control box. (Refer to section 19)
2. Unfold the control box. (Refer to section 25)
3. Disconnect the themistor terminals from main

P.W.B Assembly.

4. Remove the thermistor.
6. Re-install the components by refereing to the

above removal procedure above. (See Figure 29)

12. Synchronous Motor

1. Remove the control box. (Refer to section 19)
2. Unfold the control box. (Refer to section 25)
3. Remove the crankshaft.
4. Disconnect all the leads of the synchronous

motor.

5. Remove the 2 screws which fasten the syn-

chronous motor. (See Figure. 30)

6. Re-install the components by referring to the

above removal procedure above.

Figure 28

Figure 27

Figure 29

Figure 30