Refrigerating cycle – LG WG1805RY6 User Manual

Page 20

Advertising
background image

19 Room Air Conditioner

Disassembly

CAUTION: Discharge the refrigerant
system using a Freon

TM

Recovery

System. If there is no valve to attach the
recovery system, install one (such as a
WATCO A-1) before venting the Freon

TM

.

Leave the valve in place after servicing
the system.

13. Condenser

1. Remove the cabinet. (Refer to section 18)

2. Remove the 4 screws that fasten the brace.(Refer

to section 20)

3. Remove the 5 screws that fasten the condenser

and shroud.

4. After discharging the refrigerant completely,

unbraze the interconnecting tube at the condenser
connections.

5. Remove the condenser.

6. Re-install the component by referring to notes.

(See Figure 31)

14. evaporator

1. Remove the cabinet. (Refer to section 18)

2. Remove the 2 screws that fasten the evaporator.

3. Move the evaporator sideways carefully.

(Refer to section 20)

4. After discharging the refrigerant completely,

unbraze the interconnecting tube at the evaporator
connections.

5. Remove the evaporator.

6. Re-install the component by referring to notes.

(See Figure 32)

15. Capillary Tube

1. Remove the cabinet. (Refer to section 18)
2. After discharging the refrigerant completely,

unbraze the interconnecting tube at the capillary
tube.(See caution above)

3. Remove the capillary tube.
4. Re-install the component by referring to notes.

Refrigerating Cycle