25 Room Air Conditioner

Troubleshooting Guide

Troubleshooting Guide

Piping System

Figure 34 is a brief description of the important components and their function in what is called the refrigeration
system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.

MOTOR

COMPRESSOR

OIL

(LIQUID REFRIGERANT)

CAPILLARY TUBE

OUTSIDE COOLING
AIR FOR REFRIGERANT
PASS THROUGH

SUCTION LINE
COOL LOW PRESSURE VAPOR

COOLED
AIR

COMPLETE LIQUID
BOIL OFF POINT

LIQUID
PRESSURE
DROP

ROOM AIR HEAT LOAD

VAPOR INLET

HOT
DISCHARGED
AIR

LIQUID OUTLET

HIGH PRESSURE VAPOR

LIQUID REFRIGERANT

LOW PRESSURE VAPOR

ROOM AIR CONITIONER

EVAPORATOR COILS

CONDENSER COILS

CYCLE OF REFRIGERATION

CAPILLARY TUBE

COMPRESSOR

BLOWER

EVAPORATOR COIL

CONDENSER COIL

FAN

MOTOR

Figure 34