LG WG1805RY6 User Manual

Page 32

Advertising
background image

31 Room Air Conditioner

Troubleshooting Guide

NO

NO

NO

NO

YES

YES

YES

Is the IC01G all right?

Is the connection of

CN-DISP all right?

• Exchange the display
PCB Ass'y.

• Exchange IC01G.

• Exchange
Q01G-Q04G.

• Connect connector
to CN-DISP exactly.

Does the

Q01G~Q04G operate normally

on main PCB Ass'y?

Is the voltage of Battery

about over 2.3V?

• Exchange Receiver Ass'y.

Is the connection of

CN-DISP all right?

Is the voltage No.16

of CN-DISP on Main PCB

Ass'y DC 5V?

• Exchange the battery.

• Check the PCB pattern.

• Connect connector to
CN-DISP exactly.

NO

NO

NO

YES

YES

YES

Possible Trouble 6

Remote controller does not operate.

Possible Trouble 7

It displays abnormally on display PCB Ass'y.