Settlement of outdoor unit, Indoor unit installation – LG LCN240CP User Manual

Page 23

Advertising
background image

Service Manual 23

Installation

Bolt

Tubing connection

2. Settlement of outdoor unit

• Anchor the outdoor unit with a bolt and

nut(ø10mm(0.39inch)) tightly and horizontally on a
concrete or rigid mount.

• When installing on the wall, roof or rooftop, anchor

the mounting base securely with a nail or wire assum-
ing the influence of wind and earthquake.

• In the case when the vibration of the unit is conveyed

to the hose, secure the unit with an anti-vibration rub-
ber.

Wall

5~7mm

(0.20~0.28inch)

Indoor

Outdoor

3. Indoor Unit Installation

• The following parts is option.

Hanging Bolt - W 3/8 or M10
Nut - W 3/8 or M10
Spring Washer - M10
Plate Washer - M10

• Drill the piping hole on the wall slightly tilted to

the outdoor side using a Ø 70(2.76inch) hole-core
drill.

Set screw of
paper model (4 pieces)

Paper model
for installation

Ceiling board

150mm(5.91inch)

Adjust the same height

Ceiling board

Ceiling

Flat washer for M10

(accessory)

Keep the length of the bolt

from the bracket to 40mm(1.57inch)

Open the ceiling board
along the outer edge of the
paper model

Flat washer for M10

(accessory)

Hanging bolt

(W3/8 or M10)

Nut
(W3/8 or M10)

Nut

(W3/8 or M10)

Spring washer

(M10)

Air Conditioner body

• Tighten the nut and bolt to prevent unit falling.

CAUTION