Troubleshooting ch61, ch62, Check point – LG LCN240CP User Manual

Page 47

Advertising
background image

Service Manual 47

Troubleshooting Guide

Troubleshooting CH61, CH62

61

62

Condenser

pipe sensor

temp. high

Heat sink sensor

temp. high

• Condenser pipe sensor

detected high
temp.(65°C)(149°F)

• Heat sink sensor

detected high
temp.(85°C)(185°F)

• Check the load condition.
• Check the sensor of Condenser pipe sensor.

• Check the fan is locked.
• Check the sensor of heat sink.

Display

code

Title

Cause of error

Check point & Normal condition

Check Point

• CH 61

1. Check the install condition for over load.

(Refrigerant, Pipe length, Blocked, …)

• CH 62

1. Check the fan is locked.

2. Check the Outdoor temp. is very high.

COMP Frequency

(Hz)

Toff

°C

T1

°C

T2

°C

OFF

Normal

Normal

Normal

Heat Sink temp.