Optional postal lock, Optional color cctv camera, Postal lock installation – Linear AE-100 User Manual

Page 12: Camera installation

Advertising
background image

12

Optional Postal Lock

A postal lock can be installed in the AE-100 Entry System to provide
keyed access for the postal service. The AE-100 case is designed to
accept a U.S. Postal Service postal lock. When the postal lock is engaged
the access relay will activate.

Postal Lock Installation

1. Remove the four locknuts that retain the postal lock cover plate

and block (above the speaker on the AE-100 faceplate).

2. Remove the cover plate and block from the

four studs. Discard the plate and block.

3. Remove the faceplate’s postal lock hole plug. Discard the plug.
4. Install the postal lock assembly onto the four

studs. The postal lock’s moving plunger should
point towards the microswitch (see fi gure).

5. Secure the postal lock with the four locknuts.
NOTE: Be sure the postal lock’s plunger actuates the microswitch.

Adjust the postal lock and test the action until the microswitch fully
actuates.

6. Tighten the four locknuts after the adjustment

and testing is complete.

Optional Color CCTV Camera

Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed
inside the AE-100 Entry System. The camera provides a video signal for
viewing the area in front of the entry system.
The CAMERA connector is used to connect the camera to the AE-100.
The 4-conductor cable routes power to, and video from the camera.
The VIDEO OUT jack is the camera output for connection to a video
cable with a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59
video cable can be used. Longer cable runs may require the use of a
video amplifi er.

NOTE: The composite video signal can be viewed on a video

monitor. Alternately, a Linear ChannelPlus brand video modulator
can be used to convert the video signal to an RF signal for
installations where the camera’s picture will be viewed on television
sets tuned to a custom channel.

Camera Installation

1. Remove the two locknuts and the cover plate from the camera

mounting studs on the AE-100 faceplate. Discard the cover plate.

NOTE: A spare camera protection lens is supplied with the CCM-1

camera kit. If the AE-100’s protection lens needs replacing due to
vandalism, push the damaged protection lens out of the faceplate
and install the spare protection lens before installing the camera.

2. Mount the camera assembly on the two studs, with

the alignment hole in the camera bracket towards the
top. Secure the camera with the two locknuts.

3. Connect the camera’s cable to the AE-100’s CAMERA connector.
4. Connect the video cable to the AE-100’s VIDEO OUT connector.
5. Connect the other end of the video cable to the viewing monitor,

ChannelPlus brand video modulator, or video distribution system.

REMOVE LOCKNUTS

REMOVE PLATE & PLUG

INSTALL POSTAL LOCK

PLUNGER POINTS
TO MICROSWITCH

REPLACE LOCKNUTS

NOTE: BE SURE THE POSTAL LOCK'S PLUNGER ACTUATES THE
MICROSWITCH. ADJUST THE POSTAL LOCK MOUNTING THEN
TEST THE ACTION UNTIL THE MICROSWITCH FULLY ACTUATES

4

3

2

1

INSPECT MICROSWITCH ACTION

5

6

CONNECT WIRING HARNESS
TO CAMERA CONNECTOR

3

4

REMOVE THE LENS CAP

ATTACH CAMERA WITH TWO NUTS

1

REMOVE PLATE RETAINING NUTS

2

REMOVE THE PLATE

DRESS WIRES

WITH WIRE

TIES

CONNECT VIDEO CABLE TO
VIDEO OUT CONNECTOR

ALIGNMENT

HOLE

CAMERA

PROTECTION

LENS

Advertising