Access relay wiring, Telephone wiring – Linear AE-100 User Manual

Page 9

Advertising
background image

9

Access Relay Wiring

The access relay controls access devices, such as a door strike, magnetic
lock, automatic door, barrier gates, or automatic sliding gate. The RELAY
indicator displays the status of the relay.

Door or Pedestrian Gate Control

1. Install a low voltage electric door strike or magnetic lock

as a locking device for the door or pedestrian gate.

2. Install the power supply or transformer for the locking device. DO

NOT POWER THE AE-100 FROM THIS POWER SUPPLY.

3. Connect one wire from the power supply to

one wire from the locking device.

4. Route two wires between the locking device and the AE-100.

Connect one wire to the remaining wire of the locking device.
Connect the other wire to the remaining wire of the power supply.

5A. For a door strike, connect the wires to the AE-100

access relay COM & N.O. terminals.

5B. For a magnetic lock, connect the wires to the

AE-100 access relay COM & N.C. terminals.

Gate Control

1. Route two wires between the gate and the AE-100.
2. Connect the gate operator’s OPEN terminals to the

AE-100 access relay COM & N.O. terminals.

NOTE: For operator wiring specifi cs, refer to the gate operator’s

wiring diagram

.

Telephone Wiring

For telephone entry and programming, the AE-100 connects to a standard
telephone line. A dedicated telephone line is required.

NOTE: For multiple-unit installations, also refer to the next

section.

Important Telephone Wiring Tips

DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE

SAME CONDUIT. Route all telephone wires inside a dedicated
conduit that is at least six inches away from any AC line wiring.
All telephone wiring must be made on the “building” side of the

telephone company’s demarcation device (the terminal block
where the telephone line connects to the building).
If any security system or personal alert system at the installation is

connected to the telephone line, be sure that it is connected to the
line ahead of the AE-100 using a RJ-31X or RJ-38X interface.
Use only high-quality telephone wire. All telephone wire should be

twisted-pair with a minimum size of 24 AWG.

Typical Telephone Wiring

1A. If using the AE-100 modular connector for the telephone

connection, connect a double-ended modular cable
between the AE-100’s TELEPHONE jack and the modular
telephone jack wired to the installation’s telephone line.

1B. If using the AE-100 terminal block for the telephone

connection, connect the two telephone wires to the
two screw terminals (polarity either way).

N.C.

COM

N.O.

ACCESS
RELAY

RELAY RATING:

10 AMPS MAXIMUM @ 30 VOLTS AC

7 AMPS MAXIMUM @ 30 VOLTS DC

TYPICAL DOOR STRIKE HOOKUP

TYPICAL MAGNETIC LOCK HOOKUP

TYPICAL AUTOMATIC GATE HOOKUP

ELECTRIC

DOOR

STRIKE

DOOR

STRIKE

POWER SUPPLY

N.C.

COM

N.O.

MAGNETIC

DOOR

LOCK

DOOR

LOCK

POWER SUPPLY

N.C.

COM

N.O.

GATE

OPERATOR

OP

EN

ACCESS
RELAY

ACCESS
RELAY

TELEPHONE
TERMINALS

TELEPHONE
JACK

TO THE INCOMING

DEDICATED

TELEPHONE LINE

CONNECT THE TELEPHONE LINE
TO EITHER THE SCREW TERMINALS
OR THE RJ-11 TELEPHONE JACK

TO PREVENT LINE HUM, DO NOT ROUTE THE TELEPHONE

LINE AND THE AC WIRING INSIDE THE SAME CONDUIT!

CAUTION!

TELEPHONE LINE POLARITY

IS NOT CRITICAL