System adjustments, System diagnostics – Linear AE-100 User Manual

Page 32

Advertising
background image

32

DIGITAL

SPEECH

VOLUME

ADJUSTMENT

SPEAKERPHONE

VOLUME

ADJUSTMENT

DISPLAY

CONTRAST

ADJUSTMENT

AE-100

CIRCUIT BOARD

MORE

LESS

AE-100

CIRCUIT BOARD

POWER

PHONE

STATUS

RELAY

BATTERY

RESET

BUTTON

System Adjustments

The factory settings are suffi cient for most installations. The system can
be adjusted to customize the installation.

Digital Speech Volume Adjustment

The sound level of the tones and digital voice that the system produces
can be adjusted.

1. Locate

the

DIGITAL SPEECH VOLUME

adjustment on the main circuit board.

2. Press

the key test the digital speech level. Turn the

DIGITAL SPEECH VOLUME control adjustment clockwise
for more volume, counterclockwise for less volume.

Speakerphone Volume Adjustment

If the resident’s voice from the speaker is too loud or not loud enough, the
speaker’s volume can be adjusted.

NOTE: Adjusting the SPEAKERPHONE VOLUME too high will

prevent proper operation. This control only affects the speaker
volume, not the volume from the microphone.

1. Locate

the

SPEAKERPHONE VOLUME

adjustment on the main circuit board.

2. Make a Directory Code call to test the speaker volume. While

listening to the resident’s voice, turn the adjustment clockwise
for more volume, counterclockwise for less volume.

Display Contrast Adjustment

If the lighting in the area or the viewing angle of the display in the
installation causes the display to look too dark or too light, the display’s
contrast can be adjusted.

1. Locate

the

DISPLAY CONTRAST adjustment

on the main circuit board.

2. Turn the adjustment clockwise and counterclockwise

until display has the best visibility.

System Diagnostics

Several components on the main circuit board are for monitoring the
system during operation. When calling for technical assistance, Linear’s
Technical Services Department may ask the installer to use these
components to diagnose the system.

On-board Indicators

Five LED indicators are on the main circuit board. Refer to the fi gure for
the location of each indicator.

POWER lights when power is present at the power terminals,
fl ashes after diagnostic failure or communication failure
(to clear indicator, see Function or PPN #35).

PHONE fl ashes when the system has the incoming telephone line
seized (off-hook), lights when the system is not seizing the telephone
line (on-hook), off when there is no telephone line connection.

STATUS lights when the unit has seized the
telephone line or answered the telephone.

BATTERY lights when the backup battery voltage is OK, fl ashes when
the backup battery is charging, off if no backup battery is installed.

RELAY lights when the access relay is energized.

Reset Button

Pressing the RESET button will reboot the system’s micro controller. NO
SYSTEM INFORMATION WILL BE ERASED.
After the system reset, the system’s master code will be displayed.