A-3

INSTALLATION

INVERTEC® V311-T AC/DC TIG

A-3

5. The work terminal must be connected to a ground

within ten feet of the welder, using one of the fol-

lowing methods.

a)

A metal underground water pipe in direct con-

tact with the earth for ten feet or more.

b)

A 3/4” (19mm) galvanized pipe or a 5/8”

(16mm) solid galvanized iron, steel or copper

rod driven at least eight feet into the ground.

The ground should be securely made and the

grounding cable should be as short as possible

using cable of the same size as the work cable, or

larger. Grounding to the building frame electrical

conduit or a long pipe system can result in re-radi-

ation, effectively making these members radiating

antennas.

6.

Keep all panels securely in place.

7.

All electrical conductors within 50 ft (15.2m) of the

welder should be enclosed in grounded, rigid

metallic conduit or equivalent shielding. Flexible

metallic conduit is generally not suitable.

8.

When the welder is enclosed in a metal building,

several earth driven electrical grounds connected

(as in 5b above) around the periphery of the build-

ing are recommended.

Failure to observe these recommended installation

procedures can cause radio or TV interference prob-

lems.

RECONNECT PROCEDURE

The Invertec® V311-T AC/DC auto reconnects to

208V, 230V or 460V supply.

Fuse the input circuit with time delay fuses or delay

type

1

circuit breakers. Using fuses or circuit breakers

smaller than recommended may result in “nuisance”

shut-offs from welder inrush currents even if not weld-

ing at high currents.

The Invertec® V311-T AC/DC is recommended for

use on an individual branch circuit.

¹

Also called “inverse time” or “thermal/magnetic” circuit breakers.
These circuit breakers have a delay in tripping action that
decreases as the magnitude of the current increases.

INPUT CONNECTIONS

Be sure the voltage, phase, and frequency of the input

power is as specified on the rating plate, located on

the bottom of the machine.

ELECTRIC SHOCK can kill.

• Have a qualified electrician install

and service this equipment.

• Turn the input power OFF and unplug

the machine from the receptacle

before working on this equipment.

• Allow machine to sit for 5 minutes minimum to

allow the power capacitors to discharge before

working inside this equipment.

• Do not touch electrically hot parts.

• Machine must be plugged into a receptacle that

is grounded according to the National Electrical
Code and local codes.

• Do not remove or defeat the purpose of the

power cord ground pin.

------------------------------------------------------------

WARNING