B-5

OPERATION

B-5

3. The Mode Push Buttons and Indicators show the

current selection made by the corresponding weld

push buttons (A-F). Refer to Table B.2 for a full list

of all parameters and their ranges. Below is a

description of the function of each push button and

display:

Two-Step with Foot Pedal -This

m o d e i s o n l y a v a i l a b l e w h e n t h e

machine senses a remote amperage

control device is plugged in. It is used

w h e n a f o o t o r h a n d a m p t r o l i s

plugged in. When this trigger mode is

selected, upslope and downslope are

set to zero and non-adjustable since

the operator would manually adjust

ramp up and ramp down of the weld-

ing current using the amptrol. The

start and finish currents are linked

together and are repesented by a

parameter called Minimum Current.

(Refer to Figure B.5)

Four Step - This mode is intended to

be used with an arc start switch. It will

not function properly in remote mode

with a foot or hand amptrol plugged

in. In four step operation depressing

an arc start switch will cause the

machine to initiate the arc at the start

current level. When the switch is

released the machine will ramp up to

the maximum current over the ups-

lope time. Depressing the arc start

switch again causes the output to

ramp down to the finish current level

over the downslope time. Finally

releasing the arc start switch causes

the arc to go out. (Refer to Figure B.6)

INVERTEC® V311-T AC/DC TIG

Table B.2

DC TIG - DC TIG welding with high

frequency arc initiation.

AC TIG - AC TIG welding with high

frequency arc initiation.

DC Touch Start TIG - DC TIG welding with

lift tig arc initiation.

Stick crisp mode - for Cellulosic electrodes

like Exx10.

Stick soft mode - for E7018 Low Hydrogen

electrodes.

AC Stick Mode - for AC Stick Electrodes.

A. WELDING MODES

B. TIG TRIGGER MODES

Two Step with Arc Start Switch -

This mode is available in local or

remote modes but is typically used

with an arc start switch. Depressing

the arc start switch will initiate the arc

at the start current level and ramp up

the output to the maximum current

over the time set by the upslope time.

Releasing the switch will cause the

output amperage to ramp down to the

finish current over the downslope time

and then turn off the output. In this

mode the start current and finish cur-

rent can be independently set and

upslope and downslope times are

adjustable. (Refer to Figure B.5)

2S

2S

2S

FIGURE B.5 2-STEP OPERATION SEQUENCE

PRE-FLOW

PRE-FLOW

PRE-FLOW

PRE-FLOW

--GAS ON--

--GAS ON--

(1)

(2)

(3)

FIGURE B.6 4-STEP OPERATION SEQUENCE

PRE-FLOW

--GAS ON--

--GAS ON--

PRE-FLOW

PRE-FLOW

(3A)