OUTPUT CONNECTIONS

ELECTRIC SHOCK can kill.

• Insulate yourself from work and

ground.

• Turn the input line Switch on the

Invertec® V311T AC/DC “off” before

connecting or disconnecting output

cables or other equipment.

• Keep the electrode holder, TIG torch and cable

insulation in good condition and in place.

• Do not touch electrically live parts or electrode

with skin or wet clothing.

------------------------------------------------------------

A-5

INSTALLATION

INVERTEC® V311-T AC/DC TIG

A-5

This unit does not include a TIG torch, but one may be

purchased separately. The accessories section of this

manual lists a number of Lincoln Electric TIG torches,

and TIG Torch Starter Packs that are recommended

for use with this machine; however, any similar TIG

torch can be used. To attach the Twist-Mate Plug to a

Lincoln Torch, slide the rubber boot onto the torch

cable (enlarge the boot opening if necessary), screw

the fitting on the torch cable into the brass connector

snugly and slide the boot back over the brass connec-

tor.

O U T P U T C O N N E C T I O N F O R S T I C K

WELDING (FIGURE A.2)

First determine the proper electrode polarity for the

electrode to be used. Consult the electrode data for

this information. Then connect the output cables to

the output terminals corresponding to this polarity.

For instance, for DC(+) welding, connect the electrode

cable (which is connected to the electrode holder) to

the “+” output terminal and the work cable (which is

connected to the work clamp) to the “-” output termi-

nal. Insert the connector with the key lining up with

the keyway, and rotate clockwise; until the connection

is snug. Do not over tighten.

TIG ADAPTER

RETAINING COMPOUND

STRAIN RELIEF BOOT

TIG TORCH POWER CABLE WITH GAS FITING

FIGURE A.2

WORK CABLE

WORK CABLE

WORK CLAMP

STICK ELECTRODE

HOLDER

WORK CABLE

TIG TORCH

WARNING

OUTPUT AND GAS CONNECTION FOR

TIG WELDING (FIGURE A.1)

The TIG Torch Twist-Mate and work cable Twist-Mate

Connectors are supplied with the welder. To connect

the cables, turn the Power Switch “OFF”. Connect the

t o r c h c a b l e T w i s t - M a t e p l u g i n t o t h e D C ( - )

Electrode/Gas Output Receptacle on the front of the

welder and turn it clockwise until snug,(Do not

Overtighten). This is a quick connect terminal and also

provides the gas connection for the shielding gas to

the torch.

To avoid receiving a high frequency shock, keep

the TIG torch and cable Insulation in good condi-

tion.

___________________________________________

WORK CABLE CONNECTION

Next, connect the work cable to the “+” output terminal

in the same way.

To minimize high frequency interference, refer to

M a c h i n e G r o u n d i n g a n d H i g h F r e q u e n c y

Interference Protection section of this manual for the

proper procedure on grounding the work clamp and

work piece.