Operation – Lincoln Electric INVERTEC IM10051 User Manual

Page 21

Advertising
background image

B-6

OPERATION

B-6

Bi-Level Current – (If Enabled from

the Setup Menu) Depressing an arc

start switch and releasing will initiate

t h e a r c t o c u r r e n t l e v e l A 1 .

Depressing and releasing the arc

Start switch again will toggle to cur-

rent level A2. Each depressing and

releasing of the switch will toggle

between A1 and A2. Depressing and

holding the switch in will initiate the

down slope to the finish current level

and finally releasing the trigger will

extinguish the arc.

Spot Timer - (If Enabled from the

Setup Menu) Selecting this trigger

mode will enable a spot timer para-

meter setting to be displayed as a

welding parameter. Once the arc is

establish the machine will weld for the

time period set by the spot timer para-

meter setting. The machine will follow

the functionality of two-step in that

start current, up-slope, down-slope

and finish current can all be adjusted.

STICK TRIGGER MODES

Local - In this mode the machine

ignores any remote that is plugged.

The machine will weld at the preset

value set at the panel of the machine.

Remote - Allows the amperage to be

set with a remote potentiometer.

C. TIG PULSE MODES

Pulse On - Turns on pulse welding in

TIG mode. Changes the sequence

diagram to Pulse TIG and allows the

adjustment of the following added

parameters:

• Pulse Frequency

• % Peak Time

• Background Current

Pulse Off - Turns off pulse welding in

TIG.

D, E, & F. Memory Operation – Pressing and releas-

ing the memory location (D) button will scroll through

memory locations 1 through 10. When a memory is

recalled or saved the memory location display will

change to reversed text indicating that the current

memory parameters are active.

Normal Display Reversed Display

(Unselected)

(Selected)

Saving to Memory

• Press and hold Memory Save Button (E) until the

memory location display indicator (D) changes to a

reverse text indicating that the current parameters

are the ones in the actively selected memory.

Recalling from Memory

• Press and hold the memory recall button (F) until

the memory location display indicator (D) changes

to reversed text indicating that the stored parame-

ters are actively recalled.

When memory parameters are actively selected,

the display indicator will remain reversed until a

welding parameter is changed with the encoder

knob or until the memory location button is pressed

to scroll to a different memory location

Local/Remote Operation – The Invertec® V311-T

AC/DC, when in TIG mode, will automatically sense

when the machine has a remote device plugged into

the 6 pin MS-type connector-like a remote pendant or

a foot amptrol. If a remote device is plugged in, the

machine will automatically function in remote mode. If

no device is plugged in, the machine will function in

local mode.

In remote mode, the operation of the machine is

slightly different depending on whether the remote

device is a foot amptrol or a remote pendant. To let

the machine know what type of device is plugged in,

the operator must select the appropriate device from

the trigger mode button. (See Trigger mode descrip-

tions above for details on the difference. In stick

mode the second button on the control panel selects

local or remote operation manually. This is required

so that the user does not need to detach a foot amp-

trol to use the machine in STICK mode.

INVERTEC® V311-T AC/DC TIG