Troubleshooting, Caution – Lincoln Electric INVERTEC IM10051 User Manual

Page 31

Advertising
background image

E-2

TROUBLESHOOTING

E-2

INVERTEC® V311-T AC/DC TIG

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Excessive spatter

Craters

Inclusions

Insufficient penetration

Sticking

Porosity

Cracks

1. Long arc

2. High current

1. Fast movement of the electrode

away from piece.

1. Poor cleanliness or distribution of

the Welding passes.

2. Improper movement of the elec-

trode.

1. High progression speed.

2. Welding current too low.

3. Narrow chamfering.

1. Arc too short.

2. Current too low.

1. Humidity in electrode.

2. Long arc.

1. Current too high.

2. Dirty materials.

3. Hydrogen in weld (present on

electrode coating).

If all recommended possible areas of

misadjustment have been checked

and the problem persists, Contact

your local Lincoln Authorized Field

Service Facility.

PROBLEMS IN STICK WELDING

Advertising