Maintenance, Safety precautions, Input filter capacitor discharge procedure – Lincoln Electric INVERTEC IM10051 User Manual

Page 29: Warning

Advertising
background image

D-1

MAINTENANCE

D-1

INVERTEC® V311-T AC/DC TIG

SAFETY PRECAUTIONS

ELECTRIC SHOCK

can kill.

• Have an electrician install and ser-

vice this equipment.

• Turn the input power off at the

fuse box, disconnect or unplug

supply lines and allow machine to

sit for five minutes minimum to

allow the power capacitors to dis-

charge before working inside this

equipment.

• Do not touch electrically hot parts.

----------------------------------------------------------------------

INPUT FILTER CAPACITOR
DISCHARGE PROCEDURE

The machine has internal capacitors which are

charged to a high voltage during power-on condi-

tions. This voltage is dangerous and must be dis-

charged before the machine can be serviced.

Discharging is done automatically by the machine

each time the power is switched off. However, you

must allow the machine to sit for at least 5 min-

utes to allow time for the process to take place.

------------------------------------------------------------

ROUTINE MAINTENANCE

Prevent metal powder from accumulating near the

aeration fins and over them.

Carry out the following periodic controls on the power

source:

• Clean the power source inside by means of low-

pressure compressed air.

• Check the electric connections and all the connec-

tion cables.

• Always use gloves in compliance with the safety

standards.

WARNING

WARNING

Advertising