Avoiding wire feeding problems, Fan control, Input line voltage variations – Lincoln Electric POWER MIG SVM157-A User Manual

Page 18: Wirefeed overload protection, Welding thermal overload protection, Operation, Wire feed overload protection

Advertising
background image

OPERATION

B-6

B-6

POWER MIG 200

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

AVOIDING WIRE FEEDING
PROBLEMS

Wire feeding problems can be avoided by observing
the following gun handling procedures:

1. Do not kink or pull cable around sharp corners.
2. Keep the gun cable as straight as possible when

welding or loading electrode through cable.

3. Do not allow dolly wheels or trucks to run over

cables.

4. Keep cable clean by following maintenance instruc-

tions.

5. Use only clean, rust-free electrode. The Lincoln

electrodes have proper surface lubrication.

6. Replace contact tip when the arc starts to become

unstable or the contact tip end is fused or deformed.

7. Keep wire reel spindle brake tension to minimum

required to prevent excess reel over-travel which
may cause wire “loop-offs” from coil.

8. Use proper drive rolls and wire drive idle roll pres-

sure for wire size and type being used.

FAN CONTROL

The fan is designed to come on when input power is
applied to the POWER MIG 200 and go off when
power is removed.

INPUT LINE VOLTAGE VARIATIONS

High Line Voltage — Higher than rated input voltage
will result in output voltages higher than normal for a
given tap setting. If your input line is high, you may
want to select a lower voltage tap than given on the
recommended procedure chart.

Low Line Voltage — You may not be able to get max-
imum output from the machine if the line voltage is less
than rated input. The unit will continue to weld, but the
output may be less than normal for a given tap setting.
If your input line is low, you may want to select a high-
er voltage tap than given on the recommended proce-
dure chart.

WIRE FEED OVERLOAD
PROTECTION

The POWER MIG has solid state overload protection
of the wire drive motor. If the motor becomes over-
loaded, the protection circuitry turns off the wire feed
speed and gas solenoid. Check for proper size tip,
liner, and drive rolls, for any obstructions or bends in
the gun cable, and any other factors that would impede
the wire feeding. to resume welding, simply pull the
trigger. There is no circuit breaker to reset, as the pro-
tection is done with reliable solid state electronics.

WELDING THERMAL OVERLOAD

PROTECTION

The POWER MIG 200 has built-in protective ther-
mostats that respond to excessive temperature. They
open the wire feed and welder output circuits if the
machine exceeds the maximum safe operating tem-
perature because of a frequent overload, or high ambi-
ent temperature plus overload. The thermostats auto-
matically reset when the temperature reaches a safe
operating level and welding and feeding are allowed
again, when gun is retriggered.

Steel Thickness Wire Feed Speed/Voltage Tap Settings

Wire Dia. Gas Type

WireType

Polarity 18 gage 16 gage 14 gage 12 gage 10gage 3/16

1/4

5/16

3/8

1/2

Outershield 3/4" ESO

.035

75Ar/25CO2 OS71M

DC+

250/D

300/E

350/F 500/G *500/G

.035

100%CO2

OS71M

DC+

300/E

350/F 500/G

.045

75Ar/25CO2 OS71M

DC+

200/E 225/F 250/G 250/G *250/G

Innershield 3/8" ESO

.035

NoneReq’d NR-211MP

DC-

50/B

70/B

80/B

90/C

100/C

.045

NoneReq’d NR-211MP

DC-

50/B

70/C

90/C

110/D *130/E

.045

NoneReq’d

NR212

DC-

40/B

50/B

60/B

65/C

70/C

90/C

110/D *130/E *150/E *150/E

* Note- Requires Multiple Pass

.035 & .045 NR-211 MP is only

† Electrical Stickout

recommended for a maximum of 5/16"

TABLE B.1.

Advertising