Troubleshooting and repair, Warning – Lincoln Electric POWER MIG SVM157-A User Manual

Page 51

Advertising
background image

TROUBLESHOOTING AND REPAIR

F-17

F-17

POWER MIG 200

WIRE DRIVE MOTOR AND TACHOMETER FEEDBACK TEST

(continued)

5. Make the following voltage tests:

a. Turn the machine OFF between each

test.

b. Carefully insert the meter probes into

the lead side of plug J4. See Figure
F.4.

c. Turn the machine ON and pull the gun

trigger to conduct the voltage test.

6. If the voltage to the wire drive motor arma-

ture is zero, check the wires between plug
J4 and the wire drive motor. Also check
the electrical connector J5 for proper con-
nections and jumper plug. See the Wiring
Diagram.

7. If all wires and connectors are good and

the voltage to the drive motor armature is
zero, the control PC board may be faulty.
Replace the control PC board.

8. If the motor is running at high speed and

the armature voltage is high and uncon-
trollable, Proceed with the tachometer test.

TEST FOR SUPPLY VOLTAGE TO
TACHOMETER

1. Disconnect the main AC input power to the

machine.

2. Locate plug J4.

3. Locate the tach leads on plug J4. See

Figure F.5.

4. Connect the main input power to the

machine.

5. Make the following voltage tests:

a. Turn the machine OFF between each test.

b. Carefully insert the meter probes into the

lead side of plug J4.

6. If the 5-6 VDC is present, check the leads

to the tachometer circuit.

7. If the leads are okay and 5-6 VDC is pre-

sent, the correct voltage is being received
from the control PC board. Continue with
the supply voltage to tachometer test.

8. If the 5-6 VDC is not present and the leads

are okay, the control PC board may be
faulty, replace the control PC board. Also
check plug J5 and the jumper plug. See
Wiring Diagram.

ELECTRIC SHOCK can kill.

• Do not touch electrically live

parts such as output terminals
or internal wiring.

• All input power must be electri-

cally disconnected before pro-
ceeding.

WARNING

ELECTRIC SHOCK can kill.

• Do not touch electrically live

parts such as output terminals
or internal wiring.

• All input power must be electri-

cally disconnected before pro-
ceeding.

WARNING

FROM LEAD

FROM LEAD

FROM LEAD

Black
Armature
Lead

White
Armature
Lead

2-29 VDC

(varies depend-
ing on wire feed
speed)

FROM LEAD

FROM LEAD

FROM LEAD

Black (-)

Red (+)

5-6 VDC