Troubleshooting and repair, Output contactor replacement (continued), Output contactor – Lincoln Electric POWER MIG SVM157-A User Manual

Page 84

Advertising
background image

F-50

TROUBLESHOOTING AND REPAIR

F-50

POWER MIG 200

OUTPUT CONTACTOR REPLACEMENT (Continued)

PROCEDURE

1. Using a 5/16” nutdriver, remove the three

screws securing the tool tray.

2. Locate the output contactor. See Figure

F.23.

3. Using a 7/16” wrench, label and remove the

two thick black leads at the top of the output
contactor. Note lead and washer placement
for reassembly.

4. Remove lead 107A and note lead place-

ment. See Figure F.23.

5. Remove leads 106B and 106C. See Figure

F.23.

6. Using a 7/16” wrench, remove the three

mounting bolts from the output contactor.
Note washer positions for replacement. See
Figure F.24.

7. Replace output contactor.

8. Using a 7/16” wrench, mount the new output

contactor in its proper location.

9. Reconnect leads 106B, 106C, & 107A to

their proper terminals. See Wiring Diagram.

10. Reconnect the two thick black leads previ-

ously removed from the top of the output
contactor.

11. Replace the tool tray using a 5/16” nutdriv-

er.

107A

106C

106B

Output
Contactor

FIGURE F.23. - OUTPUT CONTACTOR LEADS