INSTALLATION

LF-72

A-6

ANALOG CONTROL CABLE

CONTROL CABLE CONNECTIONS

• All control cables can be connected end to end to

extend their length.

The control cable connecting the wire feeder to the

power source is specially made for the welding envi-

ronment.

The wire feeder power requires overcurrent protec-

tion. Connect the wire feeder only to power sources

with overcurrent protection of no more than 15 amps.

PIN

FUNCTION

LEAD#

A

Unused

-------

B

Reserved

-------

C

Welding Output Control

2

(trigger from feeder)

D

Welding Output Control

4

(trigger from feeder)

E

Remote Voltage Control

77

(“+” supply from feeder or remote)

F

Remote Voltage Control

76

(control signal from feeder or remote)

G

Remote Voltage Control

75

(“-” supply from feeder or remote)

H

Reserved

I

42 VAC

41

J

Reserve for Future Use.

K

42 VAC

42

L Reserve for Future Use.

M

Unused

-------

N

Electrode voltage from feeder

67

Do not use more than 100 ft (30.5 m) of control cable

between the wire feeder and power source.

A

I

H

G

B

F

E

D

C

J

K

N

M

L

A

B

C

D

I

E

F

G

H

J

K

L

M

N

POWER SOURCE

WIRE FEEDER