A N A L O G M I L L E R C O N T R O L C A B L E

ADAPTER K2335-1

This Lincoln Electric wire feeder may be mounted to a limit-

ed number of Miller Electric power sources. The Miller

power source must have the amphenol pin definition shown

in the table below for proper operation of the wire feeder.

Operation of Lincoln wire feeders on Miller power sources

may result in lack of high speeds or reduce pull force on

high wire feed speeds. Maximum wire feed speed for the

LF-72 operating on a Miller power source is approximately

720ipm. Be sure the Miller power source provides 24 VAC

to the wire feeder and has overcurrent protection of no more

than 15 amps. The power source must not exceed 113VDC

peak.

A

B

C

D

I

E

F

G

H

J

K

L

M

N

A

I

H

G

B

F

E

D

C

J

K

N

M

L

WIRE FEEDER

POWER SOURCE

MILLER POWER SOURCE

Pin

Function

A

24 VAC to feeder

B

Welding Output Control

C

+10VDC to feeder for remote control

D

Remote control common

E

0-10VDC from feeder for remote control.

F

Current feedback to feeder.

Scaled 0-10V. 1 V = 100 amps.

Referenced to pin D.

G

24 VAC common.

H

Arc Voltage feedback to feeder.

Scaled 0-10V. 1 V = 10 Arc volts.

Referenced to pin D.

I

J

K

L

M

N

LINCOLN WIRE FEEDER

Pin

Function

I

42 VAC feeder

D

Welding Output Control

C

Welding Output Control

E

Remote Voltage Control ("+" supply, from

power source)

G

Remote Voltage Control ("-" supply, from

power source)

F

Remote Voltage Control (control signal from

feeder or remote.)

J

Reserved for future use.

K

42 VAC to feeder

L

Reserved for future use.

N

Electrode voltage to power source (67)

Miller is a registered trademark not owned or licensed by The Lincoln Electric Company.