MAINTENANCE

D-2

Replace brushes when they wear within 1/4”(3.5mm)

of the pigtail. A complete set of replacement brushes

should be kept on hand. Lincoln brushes have a

curved face to fit the commutator. Have an experi-

enced maintenance man seat these brushes by lightly

stoning the commutator as the armature rotates at full

speed until contact is made across the full face of the

brushes. After stoning, blow out the dust with low

pressure air.

Arcing or excessive exciter brush wear indicates a

possible misaligned shaft. Have an authorized Field

Service Shop check and realign the shaft.

IDLER MAINTENANCE

Before doing electrical work, disconnect the bat-

tery.

------------------------------------------------------------------------

When installing a new battery or using a jumper bat-
tery to start the engine, be sure the battery polarity is
connected properly. The correct polarity is negative
ground. Damage to the engine alternator and the
Engine Control Unit can result from incorrect con-
nection.

1. P r o p e r o p e r a t i o n o f t h e i d l e r r e q u i r e s g o o d

grounding of the Engine Control Unit, current

sensing printed circuit board and battery.

2. If desired, the welder can be used without automat-

ic idling by setting the “Idler” switch to the “High”

position.

NAMEPLATES

Whenever routine maintenance is performed on this

machine - or at least yearly - inspect all nameplates

and labels for legibility. Replace those which are no

longer clear. Refer to the parts list for the replace-

ment item number.

P U R G I N G A I R F R O M F U E L S Y S T E M

(KUBOTA V2403M ENGINE)

Keep fuel clear of open flames or arcs, allow

engine to cool before working on the fuel system.

Wipe up any spilled fuel and do not start engine

until fumes clear.

------------------------------------------------------------------------

If the engine is running rough and you suspect air has

been trapped in the fuel system, (e.g. the engine was

allowed to run out of fuel) perform the following steps

using qualified personnel:

1. Fully open the air bleeding valve by turning it

counter clockwise, it is located on top of the fuel

injection pump next to the oil filler. (see figure D.1)

FIGURE D.1

2. Turn the engine by pressing the start button until

the engine runs smoothly (this should take approxi-

mately 10 seconds).

3. Fully close the air bleeding valve by turning it

clockwise.

Contact your Kubota Engine repair facility if problems

persist.