E-4

TROUBLESHOOTING

E-4

PIPELINER® 200D KUBOTA

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

LIGHT CODE

FAILURE DETECTED

POSSIBLE CAUSE - CORRECTIVE MEASURE

LONG 1, SHORT 1 RPM IS OVER 115% OF RATED RPM (2070 RPM) ACTUATOR IS STUCK - REMOVE ACTUATOR AND VERIFY

PLUNGER PULLS IN WHEN ENERGIZED

LONG 1, SHORT 2 LOW OIL PRESSURE DETECTED FOR 1 SECOND LOW OIL - CHECK OIL LEVEL ON DIPSTICK

FAULTY OIL PRESSURE SWITCH - CHECK THAT "WK"

STUD IS OPEN WHEN ENGINE IS RUNNING

LEAD TO OIL PRESSURE SWITCH "WK" STUD MAY BE

GROUNDED - CHECK

LONG 1, SHORT 3 "L" TERMINAL IS GROUNDED ON ALTERNATOR BROKEN OR LOOSE BELT

FOR 1 SECOND

LEAD TO "L" TERMINAL ON ALTERNATOR MAYBE

SHORTED TO GROUND- CHECK

FAULTY ALTERNATOR - CHECK

LONG 1, SHORT 4

HIGH WATER TEMPERATURE DETECTED

AMOUNT OR QUALITY OF COOLANT INCORRECT

FOR 1 SECOND

- CHECK

FAULTY WATER TEMPERATURE SWITCH - CHECK THAT

"WK" STUD IS OPEN WHEN ENGINE IS NOT RUNNING

LEAD TO WATER TEMPERATURE SWITCH MAY BE

GROUNDED - CHECK

LONG 1, SHORT 5

NOT ENABLED FOR LINCOLN PRODUCTS

LONG 2, SHORT 1 0 RPM IS DETECTED AND 12V IS DETECTED FAULTY RPM SENSOR-CHECK FOR GOOD CONNECTION

FROM "L" TERMINAL ON ALTERNATOR

FAULTY ECU - CHECK FOR 12 VOLTS ON SUPPLY LEAD

TO RPM SENSOR FROM ECU

LONG 2, SHORT 2

CURRENT TO ACTUATOR IS OUT OF LIMIT

FAULTY ACTUATOR - CHECK FOR PROPER COIL

RESISTANCE

LEADS TO ACTUATOR MAY BE OPEN OR GROUNDED

- CHECK

LONG 2, SHORT 3

NOT ENABLED FOR LINCOLN PRODUCTS

LONG 2, SHORT 4

-50C WATER TEMPERATURE DETECTED

FAULTY WATER TEMPERATURE SENSOR - CHECK FOR

PROPER RESISTANCE

LEAD TO WATER TEMPERATURE SENSOR MAY BE OPEN

- CHECK FOR CONTINUITY

LONG 2, SHORT 5 150C WATER TEMPERATURE DETECTED

FAULTY WATER TEMPERATURE SENSOR - CHECK FOR

PROPER RESISTANCE

LEAD TO WATER TEMPERATURE SENSOR MAY BE

GROUNDED - CHECK

LONG 2, SHORT 6

0 VOLTS DETECTED FROM "L" TERMINAL ON LEAD TO "L" TERMINAL ON ALTERNATOR MAY BE OPEN

ALTERNATOR FOR 1 SECOND

- CHECK FOR CONTINUITY

BROKEN OR LOOSE BELT - INSPECT

FAULTY ALTERNATOR - CHECK

LONG 2, SHORT 7

OVER 18 VOLTS DETECTED FROM ALTERNATOR INCORRECT BATTERY - INSPECT

FAULTY ALTERNATOR - CHECK

LONG 2, SHORT 8

LESS THAN 4 VOLTS TO RPM SENSOR AND/OR FAULTY ECU -CHECK FOR 12 VOLTS ON LEADS TO RPM

ACTUATOR SENSED BY ECU

SENSOR AND ACTUATOR FROM ECU