Electronic idler troubleshooting guide, Troubleshooting, Caution – Lincoln Electric PIPELINER 11498 User Manual

Page 25

Advertising
background image

E-6

TROUBLESHOOTING

PIPELINER® 200D KUBOTA

E-6

ELECTRONIC IDLER TROUBLESHOOTING GUIDE

With Idler Control Switch in the Auto Position,

Engine Will Not Return to Low Idle in Approximately 15 Seconds

After Welding and Auxiliary Loads are Removed

Set Idler Control Switch

to the Auto Position

Check for Continuity through Idler

Control Switch

Open

Closed

Check Voltage across

Replace Idler

Idler Control switch

Control Switch

12 VDC

0 VDC

Contact Kubota

Replace current

Engine Repair

Sensing PCB

Facility

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.