Troubleshooting, Caution – Lincoln Electric PIPELINER 11498 User Manual

Page 21

Advertising
background image

E-2

TROUBLESHOOTING

E-2

PIPELINER® 200D KUBOTA

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Machine fails to hold the output
(heat) consistently.

Welder starts but fails to generate
current.

Welding arc is loud and spatters
excessively.

Welding current too great or too
small compared to indication on
the dial.

Arc continuously pops out.

1.

Rough or dirty commutator.

2.

Brushes may be worn down to
Limit.

3.

Field circuit may have variable
resistance connection or inter-
mittent open circuit due to
loose connection or broken
wire.

4.

Electrode lead or work lead
connection may be poor.

5.

Wrong grade of brushes may
have been installed on gener-
ator.

6.

Field rheostat may be making
poor contact and overheating.

1.

Generator or exciter brushes
may be loose or missing.

2.

Exciter may not be operating.

3.

Field circuit of generator or
exciter may be open

4.

Exciter may have lost excita-
tion.

5.

Series field and armature cir-
cuit may be open-circuited.

1.

Current setting may be too
high.

2.

Polarity may be wrong.

1.

Exciter output low causing low
output compared to dial indica-
tion.

2.

Operating speed too low or too
high.

1.

“ C u r r e n t R a n g e S e l e c t o r ”
switch may be set at an inter-
mediate position.

If all recommended possible areas

o f m i s a d j u s t m e n t h a v e b e e n

checked and the problem persists,

C o n t a c t y o u r l o c a l L i n c o l n

Authorized Field Service Facility.

Flashing the exciter field consists of passing current through the fields using an external source of 6 to 125 volts of DC power

from a storage battery or DC generator. If using a DC generator, keep the generator turned off except when actually applying

the flashing current. To flash the fields:

1. Turn the welder off. Raise one exciter brush off the commutator.

2. On Lincoln welders, attach the positive lead from the external DC source to the right hand brushholder.

3. Carefully holding an insulated section of the negative lead from the DC source, touch its lug or clamp to the left hand

brushholder for five seconds. Pull it away quickly to minimize arcing.

Remove the lead from the right hand brushholder, replace the brush on the commutator, start the welder and the

generator

voltage should build up.