FIGURE F.25 – INPUT RECTIFIER LEAD LOCATIONS

#207
#207A

#209

A

B

C

CAP HEAD
MOUNTING
SCREW

INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT (continued)

PROCEDURE

1. Remove input power to the Pro-Cut 55.

2. Perform

the

Input Filter Capacitor

Discharge Procedure detailed earlier in this
section.

3. Locate the input rectifier and the leads con-

nected to it. See Figure F.25.

4. Identify and mark the leads connected to the

rectifier terminals.

5. With the phillips head screw driver, remove

the lead terminals connected to the rectifier
terminals.

6. Using the 3/16” allen wrench, remove the two

cap head screws and washers mounting the
input rectifier bridge to the center panel
assembly.