Installation, Recommended input wire and fuse sizes, Physical dimensions – Lincoln Electric PRO-CUT 55 SVM140-A User Manual

Page 8

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INSTALLATION

A-3

A-3

PRO-CUT 55

TECHNICAL SPECIFICATIONS (Cont’d) - PRO-CUT 55

GAS REQUIREMENTS

Required Gas Flow Rate

Required Gas Inlet Pressure

70 PSI @ 360 SCHF

80 to 150 PSI

(4.8 Bar. @ 10160 LHR)

(5.4 Bar. to 10.2 Bar.)

(6 CFM)

RECOMMENDED INPUT WIRE AND FUSE SIZES

For all plasma cutting applications based on U.S. National Electrical Code

Ambient Temperature 30°C or Less

AC Input Voltage

Fuse (Super Lag)

Type 75°C

at

Circuit Breaker

Copper Wire in Conduit AWG

60 Hertz

(Delay Type)

(IEC) Sizes

2 Input Supply Wires

1 Ground Wire

230VAC Single Phase

70 Amps

#8 (8.4mm

2

)

#10 (5.3mm

2

)

460VAC Single Phase

40 Amps

#8 (8.4mm

2

)

#10 (.3mm

2

)

230VAC Three Phase

40 Amps

#10 (5.3mm

2

)

#10 (5.3mm

2

)

460VAC Three Phase

20 Amps

#10 (5.3mm

2

)

#10 (5.3mm

2

)

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight with

Torch Cable

12.6 Inches

11.0 Inches

26.0 Inches

70 lbs. (32 kg.)

320 mm

280 mm

660 mm

(25 ft. cable)

85 lbs. (39 kg.)

(50 ft. cable)

Advertising