TROUBLESHOOTING & REPAIR

F-20

F-20

PRO-CUT 55

PRIMARY POWER BOARD RESISTANCE TEST AND

CAPACITOR VOLTAGE TEST (continued)

TEST POINT TERMINALS

ANALOG METER X10 RANGE

+ Probe

- Probe

Acceptable Meter Readings

201

207A

Greater than 1000 ohms

207A

201

Less than 100 ohms

204

207A

Greater than 1000 ohms

207A

204

Less than 100 ohms

202A

204

Greater than 1000 ohms

204

202A

Less than 100 ohms

202A

201

Greater than 1000 ohms

201

202A

Less than 100 ohms

205

203A

Greater than 1000 ohms

203A

205

Less than 100 ohms

208

203A

Greater than 1000 ohms

203A

208

Less than 100 ohms

206

208

Greater than 1000 ohms

208

206

Less than 100 ohms

206

205

Greater than 1000 ohms

205

206

Less than 100 ohms

TABLE F.2

PRIMARY POWER BOARD RESISTANCE TEST POINTS

6.

If the power board does not meet the
acceptable readings outlined in Table F.2,
the board is faulty. Replace. See Power
Board Removal and Replacement
Procedure.

NOTE: Complete power board and filter

capacitor replacement is recom-
mended.

7. If the power board “passes” the resistance

test, the IGBT portion of the board is good.
However, other circuits on the power board
may be faulty. These circuits are NOT readi-
ly tested or serviceable.

8. Reconnect leads #201, #204, #205 and #208

to their appropriate terminals.