Installation, Caution, Reconnect procedure – Lincoln Electric PRO-CUT 55 SVM140-A User Manual

Page 11

Advertising
background image

RECONNECT PROCEDURE

When received directly from the factory, the machines
are internally connected for 230 VAC. Reconnection
will be necessary if a higher input voltage is used. To
reconnect the Pro-Cut to 460 VAC or to connect back
to 230 VAC, follow the directions as outlined below.
Follow this procedure ONLY while the Pro-Cut is dis-
connected from the input power.

Failure to follow these instructions can cause immedi-
ate failure of components in the welder.

1. Open the access door on the back of the machine.

Connection instructions are also included on the
inside of the door.

2. For 230: Position the large switch to 200-230. See

Figure A.2.

For 460: Position the large switch to 380-460. See
Figure A-2.

3. Move the “A” lead to the appropriate terminal.

FIGURE A.2 – RECONNECTION DIAGRAM

INSTALLATION

A-6

A-6

PRO-CUT 55

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CAUTION

VOLTAGE = 380 - 460V

VOLTAGE = 200 - 230V

RECONNECT PROCEDURE

ELECTRIC
SHOCK
CAN KILL

• Disconnect input power before
inspecting or servicing machine.

• Do not operate with wraparound
removed.

• Do not touch electrically live parts.

• Only qualified persons should install,
use, or service this equipment.

WARNING

1. BE SURE POWER SWITCH IS OFF.

2. CONNECT LEAD 'A' TO DESIRED INPUT VOLTAGE RANGE.

440 - 460V

380 - 415V

220 - 230V

200 - 208V

3. POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.

'A'