Tests detailed in table f.1, Troubleshooting & repair, Input rectifier test (continued) – Lincoln Electric PRO-CUT 55 SVM140-A User Manual

Page 53

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-16

F-16

PRO-CUT 55

6. If the input rectifier does not meet the accept-

able readings outlined in Table F.1, the com-
ponent may be faulty. Replace.

NOTE: Before replacing the input rectifier (D1)

check the input power switch (S1) and
perform the Primary Power Board
Resistance Test.
Also check for leaky
or faulty filter capacitors.

7. If the input rectifier is good, be sure to recon-

nect leads #207, #207A and #209 to the cor-
rect terminals and torque to 31 in.-lbs. Apply
a coating of Essex D-4-8 insulating com-
pound.

8. If the input rectifier is faulty, see the Input

Rectifier Bridge Removal & Replacement
procedure. See the Wiring Diagram and
Figure F.2.

INPUT RECTIFIER TEST (continued)

TEST POINT TERMINALS

ANALOG METER X10 RANGE

+ Probe

- Probe

Acceptable Meter Readings

A

207

Greater than 1000 ohms

B

207

Greater than 1000 ohms

C

207

Greater than 1000 ohms

A

209

Less than 100 ohms

B

209

Less than 100 ohms

C

209

Less than 100 ohms

207

A

Less than 100 ohms

207

B

Less than 100 ohms

207

C

Less than 100 ohms

209

A

Greater than 1000 ohms

209

B

Greater than 1000 ohms

209

C

Greater than 1000 ohms

TABLE F.1 INPUT RECTIFIER TEST POINTS

Advertising