Operator panel service check, Operator panel service check -74, Operator panel buttons – Lexmark 4059-XXX User Manual

Page 101: Operator panel service

Advertising
background image

Diagnostic Information

2-74

4059-XXX

Operator Panel Service Check

Operator Panel Buttons Service Check

Note: Before continuing with this service check do the

“Button Test”

on page 3-9

in the diagnostic aids chapter. The operator panel cable

is a individual cable on some printers and a combination cable
assembly with the cover switch cable on later models.

4

Motor does not turn, no
gear error code 936 or User
message 201 Paper Jam
displays.

Check the voltages at J12 on the
engine board.

Pin number and voltage:

J12-1 = +24 V dc

J12-4 = +5 V dc (static) 0 V dc
(when main drive motor running)

J12-5 = + 5 V dc (static) 0 V dc
(when main drive motor running)

J12-6 = +5 V dc (static) +2.5 V dc
(when main drive motor running)

J12-7 = +5 V dc (static) 0 V dc
(when main drive motor running)

J12-8 = +5 V dc (static) +5 V dc
(when main drive motor running)

J12-11 = + 5 V dc (static) 0 V dc
(when main drive motor running)

If the voltage is incorrect, replace the
FRUs in the following order:

main drive motor assembly

engine board

FRU

Action

1

Operator Panel Assembly

If any button fails the Button Test,
replace the operator panel assembly.

FRU

Action

Advertising